PD Power
Import your LV cable schedule, place the rooms and risers on the drawings, send each cable through its riser and draw its route along the containment. The tool then lists the cables in every riser, room and containment section, with a section ID for your drawings, on a plan, an elevation and a 3D view, and in a printed report and an Excel export.
This tool is part of the Engineering Toolkit. Your projects are saved in your account, so you can come back to them from any computer.
- 25,286automated checks of the drawing and routing on 24/09/2026, each against an independent calculation
- 331equipment names read from the schedule against the owner's naming rules
- 35,560lines of wording shown in the tool read against the house rules
- 13levels of the test project aligned by grid names within half a unit of the owner's own alignment
- Last reviewed
- September 2026
- Data basis
Show the full record
Cable overall diameters and weights are read from PD Cable Database, as in PD Tray. Steel wire armoured (SWA), aluminium wire armoured (AWA), FP200, FP400, FP500 and FP600 cables are matched by family, size and cores where their “Cable Type & Size” cell is written like 4Cx35mm² SWA/XLPE/Cu, with the family straight after the size. A cable not matched to a row has no overall diameter in the tool. It is sent to PD Tray as a Custom cable, where its overall diameter and weight are entered. Everything else is read from your cable schedule and drawn on your drawings.
- Validated against
- Route segments and lengths are independently verified against calculations derived from stored route points; Updates against the new schedule. Version 1.60.0 was last validated on 09/11/2026, passing 294 automated checks, including 119 fault-injection tests.
- Each Project can be saved with new reference. Each Version can have one cable schedule, initially imported using the PD schedule template. With "Save as a new reference", a user can have several project versions, for example the consultant's design and a copy developed as the Stage 5 design.
- User can load to each Floor Plan a one-page PDF background drawing. HL (high-level containment) and LL (low-level containment) sheets are used to set the scale. All loaded drawings can be aligned. User has an option to also load the GA (general arrangement), lighting and small power drawings as a reference background, these will be aligned to the containment sheet with the Align button for each sheet, for example "Align the small power sheet".
- Drawings are stored in the browser they were loaded in and, when you save with "Store the drawings in my account too" ticked, in your account: 25 MB per drawing, 1 GB of drawings per account. Each saved reference retains its own copy, all within that 1 GB. The drawings are not in the file saved with "Export the project file".
- The 3D view is not a coordinated model. Heights are assumed. Levels line up only where their drawings are aligned with each other.
- Spacing and weight: cable run sections can be sent to PD Tray with "Send to a PD Tray report".
What's changedNovember 2026 · v1.60.0unused automatic links into risers other than the chosen ones are removed unless drawn. You can remove an empty room's unused links. Deleting rooms or floor openings joins a moved item's no-route cable to its one chosen riser where no other route changes. No-route cables can now be offered a join.
- November 2026 · v1.60.0unused automatic links into risers other than the chosen ones are removed unless drawn. You can remove an empty room's unused links. Deleting rooms or floor openings joins a moved item's no-route cable to its one chosen riser where no other route changes. No-route cables can now be offered a join.
- November 2026 · v1.59.0the report files of a project started in the tool give cables "in the project", not "in the schedule". No-route reasons no longer say "up" and "down". Messages after a move list cables by join. The Update panel and message name more of what is kept. Calculations are unchanged.
- November 2026 · v1.58.0a riser's first placement applies to every level whose drawing lines up, changing route lengths; later moves change one level only. Projects can be started without a cable schedule, and levels added later. "Start a new project" now shows both ways to start. Other calculations, reports and exports are unchanged.
- November 2026 · v1.57.0a moved item's cable with one chosen riser has that riser joined to the new place where this routes it without rerouting other items' cables. A reason names one missing join; a button makes it, whatever it reroutes. Messages name joins and rerouted cables. Other lengths, fills, reports and exports are unchanged.
- November 2026 · v1.56.0when a project with cables is open on projectdesign.io, one use of PD Power is recorded each time the page is opened, as with the other PD tools. No project name or cable is sent. The calculations, the wording in the tool, the printed report and the exports are unchanged.
- November 2026 · v1.55.0the tool is now PD Power. At an Update, your choices are kept; cleared ones stay cleared. Where a cable end you set names an item removed from the schedule, you choose which stays. 6491B, 6491X and LSX cables in PD Cable Database now have diameters, changing some section fills.
- November 2026 · v1.54.0the steps to line up a sheet or level by two pairs of points are shown one at a time. Each clicked point is numbered, and the result stays in view. The Sheet box is now shown whenever the drawing buttons are folded away. The calculations are unchanged.
- November 2026 · v1.53.0drawing a route into a riser its cable does not use no longer sends it through; its route length is not known until you choose. Feed separation places read ticked only where a tick covers them as drawn now, otherwise "check again" or "check"; one tick can cover several places.
- November 2026 · v1.52.0high-level and low-level routes that share points have separate sections, so some section IDs change. A cable with no riser chosen whose shortest route goes up a riser it does not start or end in has no route length until one is chosen. A "Save" button is next to "Undo".
- October 2026 · v1.51.0cable diameters and weights are now from PD Cable Database, as in PD Tray; the tool's copy is removed. When a project is opened, its cables are given PD Cable Database diameters; a note lists each type whose saved diameter differs. No result is shown until PD Cable Database loads.
- October 2026 · v1.50.0a route not yet drawn (a straight line) is put in the set of the sheet shown when you add, move or delete a point on it, its group or its section. Low-level routes shaped this way before 1.50.0 are in HL: draw them again with the LL sheet shown.
- October 2026 · v1.49.0saving to your account overwrites a newer save only if you choose. Drawings in this browser are kept by project, not name. Markups go into the plans PDF as you choose. Personal data export lists projects and drawings, not PDF files; erasure deletes all. The Cable Tray tool is now PD Tray.
- October 2026 · v1.48.0a Cable Tray report of a section has a run for each service its cables include, up to six. Each cable of the cable data is sent with the diameter and weight of its row. The panel of a section sent from 1.48.0 on lists what has changed since.
- October 2026 · v1.47.1after a plans or elevation PDF export, notes are listed in Recent messages, which stays open. On the Elevation tab, printed Elevation and elevation PDF, an item with its secondary feed listed first may be drawn above the item on its other feed. Route lengths and section fill are unchanged.
- October 2026 · v1.47.0from the Export menu, you can export the Elevation tab as a PDF drawing on A3 to A0 sheets, with every floor on each sheet, a key and the title block. Wider drawings are split left and right. The Elevation tab, route lengths, section fill and printed report are unchanged.
- October 2026 · v1.46.5on the Elevation tab, each riser floor's cable counts read LV, P or S, with the same numbers, and are drawn within the riser, with a key. Riser tray widths are shown only from PD Tray 2.19.2 or later. Route lengths, section fill and the printed report are unchanged.
- October 2026 · v1.46.4in a project edited outside the tool, the page no longer freezes on positions too large for the computer to hold. Cable Refs for busbar levels show with the characters they hold. Projects saved by the tool open with the same drawings, route lengths and section fill as in 1.46.3.
- October 2026 · v1.46.3riser tray widths from PD Tray's calculation are shown in the Elevation tab and riser floor panel. With floor opening names allowed for, some plans PDF section IDs become short tags, and vice versa. Route lengths, section fill, the checks, the printed report and "Copy the cable list" are unchanged.
- October 2026 · v1.46.2on the Plans tab you can mark areas to keep clear. Outside them, plans PDF labels, on white rectangles, may cover the drawing; those of items inside an area are stacked round it with leaders. Two new lines end the printed report. Calculations and plans PDFs without areas are unchanged.
- October 2026 · v1.46.1editing a rising busbar that stays in a riser keeps cable routes. Tap-offs outside a busbar's new from and to levels have no route length. Deleted floor openings stay deleted. SWA, AWA and FP400 2.5 mm² 3 core figures match the Cable Tray tool's cable list. The wording says "manually".
- October 2026 · v1.46.0named levels, levels out of number order, numbering gaps and scales across page sizes are confirmed or entered before lengths count. Minus levels, two-place Locations and part-read Riser cells are listed. Older projects' risers chosen for such cells can be replaced at Updates. Imports can stop at two columns per field.
- October 2026 · v1.45.1the tool's own program files, which hold its method, are sent only to a visitor signed in to an account that holds the Engineering Toolkit subscription. Before 1.45.1 they could be downloaded without the subscription. The calculations, the wording shown in the tool, the printed report and the exports are unchanged.
- October 2026 · v1.45.0moving, turning or aligning a board or load moves only its own cables' ends at it. Moving a riser moves its items and only the old centre points of cables going up or down through it. The message then names other cables with points left in place. Calculations are unchanged.
- October 2026 · v1.44.0renaming keeps an item's kind. After an import, Update or opening a project saved before 1.44.0, cables with a type such as MICC count as life safety until confirmed. Section fill and BS 8519 checks can change. Changeover questions show under "Not checked yet". Route lengths are unchanged.
- October 2026 · v1.43.1route lengths through a storey with no floor height above 0 m were too short and are now not known, with no length check verdict. Items in their own riser now have a drop allowance, so a check can change from within to over. Test project check results are unchanged.
- October 2026 · v1.43.0after Update imports or edits, routes not matching the cable are listed to draw again. Routes off their cable's levels are listed to delete, for cables through containment, or with both ends in one place (not fed from a rising busbar). For the latter, those routes no longer count in route length.
- October 2026 · v1.42.0changeover switches' ticked places are asked about again when any part of either feed's stretch there lies over 0.5 m from where it ran when ticked, and once if ticked on plans before 1.42.0. Feeds with no route are listed under "Not checked yet". Test project routes are unchanged.
- October 2026 · v1.41.0the exported schedule and "Schedule template" have a header: Project, Document Number, Revision, Status, Date, Issued by and Contact. Items with a level but no room or riser can be placed on their level's plan. At import, the visible sheet with the most cable rows is read. The printed report, routes and route lengths of the test project are unchanged.
- October 2026 · v1.40.0you can turn and align boards and loads, run routes along picked lines and draw a section's cables on one line. Items on riser floors of the elevation are drawn above their supply unless moved by hand. In the printed report, the sentence about busbar feed levels appears once. Routes, lengths and sections change only where you use these tools.
- October 2026 · v1.39.0a cable can change riser on its way and enter or leave its board through the floor. A cable ending at an item in its own riser needs no route on that level. In the 3D view, no tap-off outlets are marked on a rising busbar, and one whose rating is not known is drawn see-through, not at 630 A.
- October 2026 · v1.38.0an item named like PV ARRAY is now read as a photovoltaic (PV) inverter. Fire alarm supplies sharing a run with voice alarm or emergency voice communication supplies now have a line. Where a rising busbar's feeding cable has no Level (fed to), choose the level of its feed position once; until then, that cable now has no route length.
- October 2026 · v1.37.0on a crowded plans PDF sheet, sections are labelled with short tags, and the PD logo is on the plans PDF and Excel exports. In the printed report, the sentence about more than one supply is printed once. Help on labels and headings now also shows with the Tab key. The calculations, routes and section IDs are unchanged.
- October 2026 · v1.36.0dragging a section's point no longer moves other cables' routes, and a changeover switch's feeds no longer snap to each other's routes. A cable is now selected and in view after "Show on the elevation" or "Show on the level ... plan". In projects already opened in 1.33.0 or later, the calculations, printed report, plans PDF and exports are unchanged.
- October 2026 · v1.35.0one press of Ctrl+Z now takes back one change; with a tool on the Plans tab open, Ctrl+Z and "Undo" take back its last click and the tool stays open. The newest 20 copies of your projects are in the "Project" menu, under "Earlier copies in this browser". The calculations, routes, sections, printed report, plans PDF and exports are unchanged.
- October 2026 · v1.34.1on a phone, the lines shown by "Show the parts" on the Sections tab now start at the left and wrap within the table's visible width, and the "Undo", "Redo" and "Delete" buttons are under the tabs, so the page fits the screen. The calculations, routes, sections, printed report, plans PDF, exports and wording shown in the tool are unchanged.
- October 2026 · v1.34.0the Plans tab shows one Align button for the sheet chosen in the Sheet box, replacing "Align drawings" and "Align this sheet". If the project is saved in another tab or window, saving stops in the tab with the older copy until you choose which copy to keep. The calculations, routes, sections, printed report, plans PDF and exports are unchanged.
- September 2026 · v1.33.1on the Projects tab of the account page, the wording shown to a subscriber with no project saved from this tool now states that "Save to my account" and "Open a saved project" are in the "Project" menu. They have been there since 1.30.0. The wording shown in the tool, the calculations, the printed report and the exports are unchanged.
- September 2026 · v1.33.0sections now run from one junction to the next, and lines of one service within 50 mm are joined only in the two cases on the Sections tab. A joined section is given a typed identifier (ID), otherwise that of its longest part. "Send to a Cable Tray report" sends the cable's "To" as the Description. No route is changed.
- September 2026 · v1.32.0in the plans PDF, labels and title block now read the right way up and print at 7 pt or more on A3. Each sheet includes only what the Plans tab shows on its level, with a legend and an item schedule. Exported file names begin with the saved reference name. The calculations are unchanged.
- September 2026 · v1.31.0the Cables tab, the printed "Cable routes" table and the "Export the report" files have two new columns, "Drop allowance (m)" and "Length check". A route length is now shown in red where it plus the drop allowance exceeds the schedule length. With an Update from the schedule, the choices under "Serves" are now kept.
- September 2026 · v1.30.0the buttons "Start again" and "My saved projects" are replaced by "Start a new project" and "Open a saved project" in a new "Project" menu. When another project is open, you are now asked before a saved project is opened in its place. The calculations are unchanged.
- September 2026 · v1.29.3pressing the space bar or "Turn it a quarter turn" now turns a selected item a quarter turn anticlockwise on the plan; before, pressing the button turned it clockwise. A riser outline copied with "Align this riser on every level" is now counted as placed. The green, amber and grey marks are now darker.
- September 2026 · v1.29.2in the room of a changeover switch (ATS), and its riser on the level of the switch, the check that begins "Both supplies to" is no longer shown for that switch. The panel "Primary and secondary feeds" now reads "should be separated", as in BS 8519:2020 clause 7.3.
- September 2026 · v1.29.1in the 3D view, the first tap-off outlet on a rising busbar is now 763 mm above the floor from 500 A and 865 mm below 500 A: the heights in the Schneider Electric Canalis KSR catalogue. Notes and guide steps now match the tool and BS 8519:2020.
- September 2026 · v1.29.0a busbar in a riser is now drawn in the 3D view as a rising busbar, to the Schneider Electric Canalis KSR catalogue sizes (100 to 1000 A). Each busbar has a new "Rating" list, used only for the 3D view. The printed report and the exports are unchanged.
- September 2026 · v1.28.0on the Overview tab, the cables under "Cables with both ends in one place" are now grouped, with the connections to check first. The button "Passes through the floor at a hole…" now reads "Add a floor opening for this cable". The printed report and the exports are unchanged.
- September 2026 · v1.27.0the supply to a fire alarm, voice alarm, emergency voice communication or emergency lighting panel is taken out of the BS 8519 checks, as BS 8519 gives no recommendations for installations to BS 5839-1, BS 5839-8, BS 5839-9 and BS 5266-1 (BS 8519:2020 clause 1). Each load and UPS now has a "Panel of" list.
- September 2026 · v1.26.1only the wording shown in the tool has changed. For a changeover switch (ATS) that serves life safety or other critical systems, the paragraph on the 120 minute fire-rated enclosure now reads "shall be separated"; before, it read "must be separated".
- September 2026 · v1.26.0each changeover switch now has a "Serves" list: life safety, other critical systems (BS 8519:2020 clause 3.6), or business continuity or resilience, not life safety. A cable to or from a switch serving life safety or other critical systems now counts as life safety, whatever its service in the schedule. The route lengths are unchanged.
- September 2026 · v1.25.0the controls of the earlier links method are taken out, because cable routes are now the only method. The Risers and links tab is now called Risers and rooms. A project saved with links still opens. The calculations, the route lengths and the section IDs are unchanged.
- September 2026 · v1.24.0a cable is now shown as "Routed" only once its route is drawn on every level it passes; until then, one with its riser chosen, or no riser needed, has the new state "Route not drawn yet". The route length of a cable set to "no riser, through the floor" now includes the floor height.
- September 2026 · v1.23.1a double-click on the Elevation tab now opens the board editor of the board under the pointer, and deletes the route point under the pointer on the line of a selected link. In 1.23.0 these double-clicks did nothing. The calculations, the printed report and the exports are unchanged.
- September 2026 · v1.23.0a cable's route length is now the route drawn on the plans, with the riser floors, a floor it passes through and the local run at each end. It is shown once the route is drawn on every level the cable passes and each of those levels has a scale.
- September 2026 · v1.22.0boards and equipment are now drawn to size: on the plan, each board, changeover switch, UPS, generator, transformer, cut-out and EV charger has an outline of its standard size, and in the 3D view each has its shape. The plan exported as a PDF shows the outlines. The calculations are unchanged.
- September 2026 · v1.21.1with an Update from the schedule, only the fields changed in the tool are now kept as your changes; the schedule's other revisions are still taken. Where a cable reference is repeated, each row now has its own cable, named C1, C1 (2) and so on. The calculations are unchanged.
- September 2026 · v1.21.0the warnings no longer list what has been settled in the tool, such as an item put in a room by hand. The width check is removed; a section's cables can be sent to the Cable Tray tool with "Send to a Cable Tray report". The calculations are unchanged.
- September 2026 · v1.20.2the messages on moving a floor opening now say whether it moves on both levels or one. A cable between two levels again goes through a riser where the route starts or ends at its own board inside that riser's outline and neither board is in that riser, as in 1.19.3.
- September 2026 · v1.20.1a double-click on the plan now deletes the route point or corner under the pointer, on a cable, a section, the ticked cables or a room or riser outline. In 1.20.0 these double-clicks deleted nothing. The calculations, the printed report and the exports are unchanged.
- September 2026 · v1.20.0floor openings are now round: on the plan an opening is a circle at its true size, at least 300 mm across. Where both levels' drawings are the same sheet size and scale, an opening moved on one level is moved on the other too. The calculations are unchanged.
- September 2026 · v1.19.3the panel of a section now names its two ends in the direction of supply: "It runs from" the end the cables are fed from, "to" the end they go to. Before, a section could read the wrong way round; the calculations and the exports were right.
- September 2026 · v1.19.2"Start again" is harder to press by mistake. You are now asked first, with the choice to save, and the project is cleared only once you tick that you want to clear it. Pressing "Bring it back" restores the cleared project, even after the page is reloaded.
- September 2026 · v1.19.1the top of the Plans tab is two rows shorter. Once the sheet shown has a drawing, the Sheet box and the drawing buttons are folded away, and are opened and folded with "Show the drawing buttons" and "Hide the drawing buttons". On a level with no drawing, all are shown.
- September 2026 · v1.19.0drawing a route works again: from 1.9.3, no more points could be added with "Draw its route" after the first click. The search box above the plan now lists boards, loads, rooms, risers, sections and cables as you type. Choosing a result opens the plan at its level with the item selected.
- September 2026 · v1.18.2in the check of the two feeds of an ATS, the gap is now the typical gap along the stretch, for example "about 0.21 m apart for 7.5 m". Before, it was given at the closest point, which beside a crossing or a joint could read "within 0.03 m". Nothing else changed.
- September 2026 · v1.18.1the two feeds of an ATS are now checked in its own room; before, feeds side by side in a large plant room were not reported. Only the final connection is left out: the part of each feed within 2 m of the ATS, and the final rise into the ATS riser.
- September 2026 · v1.18.0feeds into a changeover switch are now shown as primary (blue) or secondary (red), and other cables as life safety (red) or LV (charcoal). The two feeds of each ATS are now checked for separation (BS 8519:2020 clauses 7.1 and 7.3): places where they run within 1 m or cross are marked in red.
- September 2026 · v1.17.0a route point dragged on the plan now snaps to a board, a riser, or a nearby point or line of another route. A section's panel now lists the cables beside the whole of it, within 0.3 m, with a button to join the ticked cables to it. Nothing else changed.
- September 2026 · v1.16.0some cables on a section can now have their route adjusted on their own: tick them and press "Adjust the route of the ticked cables only". On the plan exported as a PDF, room and riser names not moved now print at the top left of their outline. Nothing else changed.
- September 2026 · v1.15.0the word "(pinned)" is no longer shown in riser and room names. A board or load name can now be moved on its own: double-click it on the plan, then drag it. The plan exported as a PDF shows moved names where they are, and boards and loads now print above the routes.
- September 2026 · v1.14.3a cable is now drawn on a level it only crosses. A cable's route on the Cables tab, in the report and exported schedule now reads, for example, "AB2-014 to R14 (B2), then riser R14, then R14 to A0L-024 (0L)", in place of the tool's own link numbers.
- September 2026 · v1.14.2the "Line on the elevation" part of a section or cable panel names its two boxes, Line shape and Line style, each starting at "as on the Elevation tab", and names the stretches it applies to by their two ends (for example "from AB2-014 to R14 on level B2") instead of the tool's own link numbers. Nothing else changed.
- September 2026 · v1.14.1a floor opening can now be made in two ways: select a section or cable, press "Passes through the floor at a hole" and click the hole on the drawing; or right-click the hole, choose "A cable passes through the floor here", tick the cables and press "Make the floor opening here". Nothing else changed.
- September 2026 · v1.14.0a floor opening can now be made at a drilled hole: right-click the hole on the upper level, tick the cables and press "Make a floor opening here for the cables ticked". Floor openings are listed on the Risers and links tab, as a schedule of penetrations to be fire stopped.
- September 2026 · v1.13.0when a schedule is imported into an open project, the changes an Update would make are now listed before anything is changed, with "Apply the update" or "Cancel". When a board is placed outside any room and the room number typed already exists, that room can now be moved to the point.
- September 2026 · v1.12.1on the Risers and links tab, the riser and room lists each have a search box and can be sorted by their headings. While a room number is typed, the name of an existing room with that number is shown, with "Show it". The Distribution tab is now a table.
- September 2026 · v1.12.0each cable's panel now has "What this cable connects", where the board it is fed from and the board it feeds are chosen from a list. With an Update from the schedule, changes made in the tool to a cable, and cables deleted in the tool, are now kept.
- September 2026 · v1.11.1a panel that lists cables now opens wider, up to 600 pixels, with the reference, From and To of each cable on one line. Its width can be set with a grip on its left edge, and a double-click on the grip switches between wide and normal. Nothing else changed.
- September 2026 · v1.11.0a reminder to save is now shown every 15 minutes while the project has changes not saved in your account, with "Save to my account", "Not now" and "Stop the reminders", and a choice of 5, 10, 15 or 30 minutes or 1 hour.
- September 2026 · v1.10.0every cable panel now has a comment box and a tick "A change to the original design". The Cables tab has filters "With a comment" and "Design changes", and cables with a comment can be marked with "Highlight". The exported schedule has columns PD comment, PD design change and PD comment date.
- September 2026 · v1.9.3the panel of a selected section now lists "Other cables along this section", nearest first. Tick the ones that run this way and press "Follow this section with the cables ticked": each is given the section's path, and the rest of its route is kept. Nothing else changed.
- September 2026 · v1.9.2a cable with both ends on one level no longer goes up one riser and down another to reach the far end: where no link joined the two risers on its own level, that link is now added. The drawing panel on the Plans tab is taller. Nothing else changed.
- September 2026 · v1.9.1a board or load can now be moved with the right-click menu on a plan: "Move a room, riser or board here" also lists the boards and loads of the level. A board is put on the point clicked, and its routes move with it. Nothing else changed.
- September 2026 · v1.9.0the four export buttons are now one "Export" button with a list. In "Align drawings" the two buttons now read "Mark this level as checked, next level" and "Close the wizard, changes kept (Esc)". On the Elevation tab, a line leaving a board is now drawn round a board stacked under it. Nothing else changed.
- September 2026 · v1.8.9in "Align drawings", the tick "Only the drawing moves" now says to use it when the risers are right on the building and only the drawing under them is out. With "Move a room or riser here" on a pinned room, you are now asked "Unpin it and move it here?". Nothing else changed.
- September 2026 · v1.8.8the top of the Plans tab is tidier: each label is on one line with its box, the file name and its note share a line, with "Move it to" and "Remove this sheet" on a line of their own, and the zoom buttons and key are on the line below. Nothing else changed.
- September 2026 · v1.8.7"Set the scale" shows its two ways as two boxes side by side, both shaded: "1. From a dimension you know", marked as the one waiting for your clicks, and "2. From the title block". One Cancel serves both. Nothing in the calculations changed.
- September 2026 · v1.8.6"My saved projects" lists the account's projects again. From 1.7.0 the list came back empty, because the code that added the account total to the answer returned nothing. Nothing else changed.
- September 2026 · v1.8.5a PDF with more than one page is no longer loaded; the message names the page count and says to export the sheet on its own as a one-page PDF. The page box beside the file name is removed. Sheets already loaded stay as they are.
- September 2026 · v1.8.4on the Plans tab, "Move it to" now lists other levels as well as this level's other sheets, and a sheet can be taken off a level with "Remove this sheet". "Align drawings" has a new tick, "Only the drawing moves", for when only the drawing under the risers is out.
- September 2026 · v1.8.3"Align this riser on every level" and "Align every riser on every level" now work from a level with no drawing: on every other level without one, the riser is given the same outline and position. A building with typical floors can be set up on blank sheets and the drawings loaded later.
- September 2026 · v1.8.2"Set the scale" names its two ways as options 1 and 2: from a dimension you know (click its two ends on the drawing and type the length, as before), or from the scale in the title block. Both were there; the first read as plain text beside the second. The "Move it to" box is narrower. Nothing else changed.
- September 2026 · v1.8.1the Sheet box on the Plans tab is now shown before any drawing is loaded, so you choose the sheet (HL or LL containment, GA, lighting or small power) before pressing Load. A sheet loaded as the wrong one can be moved with "Move it to".
- September 2026 · v1.8.0each level's Sheet box now lists HL, LL, GA (general arrangement), Lighting and Small power. A GA, lighting or small power sheet is drawn at its own size and placed with "Align this sheet". A right-click on the drawing now opens "Move a room or riser here".
- September 2026 · v1.7.0a selected section has "Send to a Cable Tray report": the section is saved in your account as a Cable Tray report with its cables filled in. Once drawn from its PDF, a sheet reappears in about a second in the same browser. Your account now holds 1 GB of drawings, not 300 MB.
- September 2026 · v1.6.0on the Plans tab, a GA, a lighting and a small power sheet can now be loaded on a level with a drawing, with "Load a reference sheet (PDF)", and shown faint under the HL or LL sheet, so the containment can be placed against walls, luminaires and outlets.
- September 2026 · v1.5.2the plan markup PDFs now look like markups: the sheet is washed out to 30 %, the routes are heavier, and a PD title block at the bottom right states the project, level, set, reference, date and tool version. The drawing limits are 25 MB per drawing and 300 MB per account.
- September 2026 · v1.5.1a drawing already in the account is not sent again on the next save (the account keeps the file name with spaces made into hyphens, and the check read that as a different drawing). Nothing else changed.
- September 2026 · v1.5.0the report can now be exported as Word, Excel, CSV or text with "Export the report"; the drawings and 3D pictures stay in the printed report. With "Export this plan (PDF)", the sheet shown is exported as a markup, and with "Export the plans (PDF)", every level with a drawing is exported in one PDF.
- September 2026 · v1.4.0each level can now have two drawing sets, chosen in the Sheet box: HL (high-level containment) and LL (low-level). In the 3D view, HL routes are at the floor height less 300 mm (never under 2700 mm) and LL routes 100 mm above the floor. Section IDs now show the set, for example CS-B2-014-HL-001.
- September 2026 · v1.3.0the drawings can now be stored in your account: with the tick in "Save to my account", on by default, every drawing loaded is stored, up to 40 MB each and 600 MB per account. When a project is opened from the account, its drawings are loaded on any computer.
- September 2026 · v1.2.6the project chosen when saving is now shown on the account page. With a reference already saved, "Save to my account" has "Update", which replaces it, and "Save as a new reference", which keeps both. "Print the report" opens a window of its own, without the site's header, menu and footer. Nothing else changed.
- September 2026 · v1.2.5Undo, Redo and Delete have moved out of the file toolbar into a group of their own at the right of the tab bar, so the editing buttons sit apart from the file, account and print buttons. Nothing else changed.
- September 2026 · v1.2.4the two project-file buttons read "Export the project file" and "Import a project file". Nothing else changed.
- September 2026 · v1.2.3in "Save to my account" the box under Project is now called Reference name, and the list of saved projects has a Reference column. Two buttons are renamed: "Export the project file" (a file on your computer, without the drawings) and "Import a project file". Nothing else changed.
- September 2026 · v1.2.2the scale can now be set from the title block: type the ratio and the sheet size it is stated for, and a 1:100 A1 drawing saved as an A3 page is read as 1:200. When a drawing is swapped for another sheet size, the old scale is dropped and a message says so.
- September 2026 · v1.2.1the cards, the walk, the picker's list and the messages the tool opens now sit in front of the site's header, which stays at the top of the page as you scroll and was covering them. Nothing else changed.
- September 2026 · v1.2.0when you press "Save to my account", you are now asked which project the schedule belongs to, from the same list of projects as on your account page, or a new one. The saved copy is listed under that project in the PD Power Distribution card of the account page.
- September 2026 · v1.1.3the tool is now called PD Power Distribution, and its address is projectdesign.io/power-distribution/ (the old address forwards to it). The "Show me how" walk, the question boxes, the board card and the messages have their own styling on the site again.
- September 2026 · v1.1.2on the account page the Power Distribution Routes projects are listed above the reports, where they are seen without scrolling, and the Saved date is shown in UK time (a project saved after midnight showed the day before). Nothing else changed.
- September 2026 · v1.1.1the projects saved from the tool are listed on the account page as well, under My Projects, each with an Open link; until now they were listed only inside the tool. After "Save to my account" the list of saved projects opens, with the project just saved marked, so the save is seen. Nothing else changed.
- September 2026 · v1.1.0one drawing can now be used for several levels: with "Use this drawing for other levels", the levels ticked are given the drawing with its scale and alignment. A riser can now be aligned on a level with no drawing. The site pop-ups, which had failed since 1.0.0, open again.
- September 2026 · v1.0.9a cable can now be sent through a different riser from the plan: drag the blue square at the end of its drawn route away from its board into another riser outline. The cable's card on the Plans tab now has "Change the riser", as on the Cables tab. Nothing else changed.
- September 2026 · v1.0.8when no level has a drawing scale, a message inside the 3D view now says so and says to set the scale on the Plans tab; before, the view was blank. The cable picker on the Plans tab has dark lettering. The calculations are unchanged.
- September 2026 · v1.0.7the Find box and the cable picker on the Plans tab are readable again; before, under the site's own styling, the Find box font was larger and the picker lettering was faint. The calculations are unchanged.
- September 2026 · v1.0.6the tool header and the tool card on the Tools page now show the same version number. Until now the header showed the tool's own number (0.75.0) and the card the plugin's (1.0.5); from this release there is one number. Nothing else changed.
- September 2026 · v1.0.5a drawing can now be loaded on the site: the two files of the PDF reader are now .js files, not .mjs. The buttons in the tool have dark lettering again, and a button that cannot be pressed yet is shown faded. The calculations are unchanged.
- September 2026 · v1.0.4the lettering on the two buttons shown to a visitor is now white. The rule in 1.0.3 named the buttons as if they sat inside the tool's wrapper, and they sit on it, so it matched nothing. Nothing in the tool changed.
- September 2026 · v1.0.3the address of every file loaded for the tool now changes with the plugin version as well as the tool version, so a browser that has an older copy fetches the new one. Nothing in the tool changed.
- September 2026 · v1.0.2the tool's header on the site had white lettering on a white band, because the colours the stylesheet uses were left behind when it was scoped to the tool. They now travel with it. The calculations, the wording shown in the tool, the printed report and the exports are unchanged.
- September 2026 · v1.0.1the plugin could not be activated on the site, because its internal names began with PDPR, which the PD_Projects plugin already uses. Every internal name now begins with PDRT. Nothing in the tool changed.
- September 2026 · v1.0.0this is the first version on the site, for Engineering Toolkit subscribers. You can import an LV cable schedule, place rooms and risers on the drawings and draw cable routes along the containment. The cables in every riser, room and containment section are listed with a section ID, in the printed report and Excel export.